CRT60-74LX
10.4
Vibration Specifications
The weighted effective acceleration value, determined according to EN 1033 and
ISO 2631, is:
■ For whole body: 0.2 m/s
■ For hand/arm: 1.4 m/s
The sound specifications were obtained with the unit operating on fully cured,
water-wetted concrete at working engine speed. Vibration specifications for whole
body vibration were recorded at the operator's seat. Vibration specifications for
hand/arm vibration were recorded at the right joystick.
Measurements for both sound and vibration specifications were recorded with the
unit operating at full throttle, hovering on cured concrete, with combination blades
pitched at 7 degrees.
Vibration
Hand-transmitted vibration was measured per ISO 5349-1. This measurement
Uncertainties
includes an uncertainty of 1.5 m/sec
Whole body vibration was measured per ISO 2631-1. This measurement includes
an uncertainty of 0.3 m/sec
wc_td000730en2.fm
2
at the seat; 0.3 m/s
2
2
.
2
.
103
Technical Data
2
at the footrest