York Predator XP Series Installation Manual page 4

Hide thumbs Also See for Predator XP Series:
Table of Contents

Advertisement

998659-YIM-C-0614
Nomenclature
X P 090 C00 A 2 A AA 6 0 1 2 4 A
Product Category
X = HP, Single Pkg., R-410A
Product Identifier
P = 11.0 EER HP
Nominal Cooling Capacity
078 = 6.5 Ton
090 = 7.5 Ton
102 = 8.5 Ton
120 = 10.0 Ton
150 = 12.5 Ton
Heat Type and Nominal Heat Capacity
C00 = Cooling Only. No heat installed
Electric Heat Options
E09 = 9 KW
E18 = 18 KW
E24 = 24 KW
E36 = 36 KW
E54 = 54 KW
A = Std. Motor
D = Std. Motor/Motorized Damper (Downflow Only)
H = Std Motor/Low Leak Econ/Barometric Relief
(Downflow, Slab Economizer Only)
J = Std Motor/Low Leak Econ/Power Exhaust (Downflow,
Slab Economizer Only)
E = Std Motor/Horizontal Economizer (No Baro)
N = Hi Static
R = Hi Static/Motorized Damper (Downflow Only)
V = Hi Static Mtr/Low Leak Econ/Barometric Relief
(Downflow, Slab Economizer Only)
W = Hi Static Mtr/Low Leak Econ/Power Exhaust
(Downflow, Slab Economizer Only)
S = Hi Static Mtr/Horizontal Economizer (No Baro)
4
6.5-12.5 Ton York
Airflow
Voltage
2 = 208/230-3-60
4 = 460-3-60
5 = 575-3-60
®
Model Number Nomenclature
These four digits will not be assigned until a quote is requested, or an order placed.
SS Drain Pan
CPC Controller, DFS, APS
Johnson Controller, DFS, APS
Honeywell Controller, DFS, APS
Novar Controller, DFS, APS
Simplicity Intellicomfort II Controller
Simplicity Intellicomfort II Controller w/Simplicity®LINC
IntelliSpeed with VFD
IntelliSpeed, VFD and Manual Bypass
IntelliSpeed, VFD Ready (for customer-provided, field-installed drive)
2" Pleated Filters, MERV 7
4" Pleated Filters, MERV 13
BAS Ready Economizer (2-10 V.D.C. Actuator without a Controller)
Shipping Bag
Any Combination of Additional Options that Don't Have an Option Code Pre-assigned
Product Generation
6 = Sixth Generation
AA = None
AB = Phase Monitor
AC = Coil Guard
AD = Dirty Filter Switch
AE = Phase Monitor & Coil Guard
AF = Phase Monitor & Dirty Filter Switch
AG = Coil Guard & Dirty Filter Switch
AH = Phase Monitor, Coil Guard & Dirty Filter Switch
ZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will be
located in digits 15-18.
Installation Options
A = No Options Installed
B = Option 1
C = Option 2
D = Options 1 & 2
E = Option 3
F = Option 4
G = Options 1 & 3
H = Options 1 & 4
J = Options 1, 2 & 3
K = Options 1, 2, & 4
L = Options 1,3 & 4
M = Options 1, 2, 3, & 4
N = Options 2 & 3
P = Options 2 & 4
Q = Options 2, 3, & 4
R = Options 3 & 4
S = Option 5
T = Options 1 & 5
U = Options 1, 3, & 5
V = Options 1, 4, & 5
W = Options 1, 3, 4, & 5
X = Options 3 & 5
Y = Options 4 & 5
Z = Options 3, 4 & 5
Options
1 = Disconnect
2 = Non-Pwr'd Conv. Outlet
3 = Smoke Detector S.A.
4 = Smoke Detector R.A.
5 = Pwr'd Conv. Outlet
Product Style
A = Style A
B = Style B
C = Style C
Configuration Options (not required for all units)
Additional Options
RC = Coil Guard, Shipping Bag & American Flag
TA = Technicoat Condenser Coil
TJ = Technicoat Evaporator Coil
TS = Technicoat Evaporator & Condenser Coils
EA = ElectroFin Condenser Coil
EJ = ElectroFin Evaporator Coil
ES = ElectroFin Cond & Evap Coils
Johnson Controls Unitary Products