Wireless connection kit for intellitouch and easytouch control systems (12 pages)
Summary of Contents for Pentair EasyTouch
Page 1
EASYTOUCH / INTELLITOUCH ® ® CONTROL SYSTEM UPGRADE TO INTELLICENTER™ CONTROL SYSTEM (For Systems 2012 or Newer) Air Temp 65° F 8:00 A.M. 78° 84° Pool Features Lights 6.50 Schedule Usage Chemistry Status INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS...
Page 2
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide CUSTOMER SERVICE / TECHNICAL SUPPORT Technical Support Customer Service Sanford, North Carolina (8 A.M. to 8.30 PM ET) 8 AM to 5.30 PM — Eastern and Pacific Times Phone: (919) 566-8000 Phone: (800) 831-7133...
Page 3
This guide provides installation and operation instructions for the IntelliCenter Control System. Consult ™ Pentair Water Pool and Spa, Inc. with any questions regarding this equipment (see “Customer Service/Technical Support”, page ii). Attention Installer: This guide contains important information about the installation, operation and safe usage of this product.
Page 4
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide IMPORTANT WARNING AND SAFETY INSTRUCTIONS Water temperature in excess of 100° F (37.7° C) may be hazardous to your health. Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above normal body temperature of 98.6°...
Page 5
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide IMPORTANT WARNING AND SAFETY INSTRUCTIONS FCC Regulatory Safety Notice FCC non-modification statement: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Page 6
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide Pentair Water Pool and Spa IMPORTANT SAFETY INSTRUCTIONS For Installation of Electrical Controls at Equipment Pad (ON/OFF Switches, Timers, and Automation Control Systems) Install all electrical controls at equipment pad, such as on/off switches, timers, and control systems, etc.
Page 7
IntelliTouch Control System ® ® Upgrade Installation Kits Overview This manual describes how to upgrade an EasyTouch or IntelliTouch Control System to the IntelliCenter Control System. The Upgrade Installation Kits apply to the following: • EasyTouch PL4/PSL4 Control Systems, EasyTouch Control Systems ®...
Page 8
Note: INSTALLING THE WIRELESS ANTENNA KIT. See IntelliCenter Control System Installation Guide. CAUTION: If there are EasyTouch or IntelliTouch Control System installed accessories, such as an Indoor Control Panel or Wireless Remote, they will no longer function after installing the IntelliCenter Control System Upgrade Kit.
Page 10
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide Removing the Existing Outdoor Control Panel The following upgrade installation instructions are for EasyTouch PL4/PSL4, EasyTouch or IntelliTouch ® Control Systems using the 2012 or later (square low voltage circuit breakers configuration on bezel) Load Center or Power Center.
Page 11
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide Removing the Existing Outdoor Control Panel (Continued) 5. Disconnect the transformer connector and if necessary the SCG Board connector (RS-485) from the existing Outdoor Control Panel circuit board. 6. Disconnect all other connections from the circuit board.
Page 12
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide Install the new 4A and 5A Low Voltage Circuit Breakers and System Transformer Remove the existing 3/4 AMP circuit breakers from circuit breaker bracket: See Figure 4 below. 1. Remove bracket screws to access the circuit breakers: Remove the two side screws on the side of the enclosure, and the screw on the back of the enclosure securing the circuit breaker bracket with the SCG ground wire if present.
Page 13
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide Install the new 4A and 5A Low Voltage Circuit Breakers and System Transformer Continued Wiring the new System Transformer (P/N 522102) The IntelliCenter Control System Load Center or Power Center System Transformer can be wired for ™...
Page 14
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide 4. Reconnect 120 VAC Transformer Wires: Reconnect the System Transformer wires (see wiring diagram below) to the Load Center (or Power Center) circuit breaker. Circuit Breakers Route transformer secondary wires up through channel opening...
Page 15
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide 5. Install the circuit breaker bracket with the circuit breakers onto the enclosure, and secure it with two #8-32 x 3/8” screws (7). 6. Secure the circuit breaker bracket onto the back of the enclosure with #8-32 x 3/8” screw.
Page 16
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide Installing the IntelliCenter™ Control System Outdoor Control Panel 1. Install the IntelliCenter Outdoor Control Panel (1) and Bezel: Mount the Outdoor Control Panel and bezel onto the enclosure. Install the two screws to secure the bezel to the enclosure.
Page 17
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide AUX5 AUX6 AUX7 AUX8 AUX9 Wiring Diagram label for IntelliCenter Control System Upgrade Kit. *522612* Figure 11. IntelliCenter™ Control System Circuit Board (with optional Expansion Boards shown) Installing the Wiring Label on the Enclosure Front Door 1.
Page 18
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide NOTES Note: Refer to page 3 where (parts index number) is shown...
Page 19
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide NOTES Note: Refer to page 3 where (parts index number) is shown...