Programming special functions
1.2 Setting the detergent dosage
concentration level
If the dispensing method has been
programmed for liquid detergent, you
can adjust the dispensing
concentration.
Set the dispensing concentration
according to the detergent
manufacturer's recommendations
and the applications.
Example: If the manufacturer
recommends a detergent concentration
of 0.5%, a value of 0.50 should be set.
^ Select programming level 2.
^ Press z until 2.02 is displayed.
^ Press the A button. The liquid
detergent dosage concentration is
displayed in %.
0.00 - 1.00 = 0.0 % - 1 % dosage
concentration level
(factory default setting 0.20 = 0.2 %).
^ Press and hold A until the desired
value appears in the display.
The dosage concentration level has
been set.
Value set:
36
If you do not want to make any other
setting changes in this programming
level, proceed to step 1.4.
1.3 Venting the dispensing system
^ Select programming level 2.
^ Press z until 2.03 is displayed.
^ Press A. The display shows do1.
^ Press the A button.
The dispensing system will be vented
automatically. 0 will appear in the
display when the venting process is
completed.
If you do not want to make any other
setting changes in this programming
level, proceed to step 1.4.
1.4 To save your changes
^ Press the 6 button. The display
shows SP.
^ Press the 6 button again. The
change has been saved.
^ Turn the machine off with the
Z button.