Adjust The Electrostatics - Graco PRO Auto Xs Series Instructions-Parts List Manual

Automatic electrostatic air spray gun
Table of Contents

Advertisement

Operation

Adjust the Electrostatics

1. Shut off the fluid supply.
2. Trigger the gun, then turn on the turbine air (TA).
See F
12.
IGURE
3. Refer to Table 4 to set the proper pressure at the
turbine air hose inlet when air is flowing. Do not
exceed these pressures as there is no added bene-
fit and turbine life could be reduced.
20
Table 4: Dynamic Turbine Air Pressures
Turbine Air
Air pressure at turbine air hose
Hose Length
ft (m)
15 (4.6)
25 (7.6)
36 (11)
50 (15.3)
75 (22.9)
100 (30.5)
4. Check the voltage output of the gun using a high
voltage probe and meter or by reading the ES (kV)
Display Module.
The gun's normal high voltage reading is 60-70 kV. If a
ball end high voltage measurement probe is used, the
gun voltage will rise to about 85 kV. This will happen
with all resistive electrostatic guns.
See Electrical Troubleshooting on page 31 to correct
voltage problems.
inlet for full voltage
psi (bar, MPa)
54 (3.8, 0.38)
55 (3.85, 0.38)
56 (3.9, 0.39)
57 (4.0, 0.40)
59 (4.1, 0.41)
61 (4.3, 0.43)
309297K

Advertisement

Table of Contents
loading

Table of Contents