Electrode Replacement - Graco PRO Auto Xs Series Instructions-Parts List Manual

Automatic electrostatic air spray gun
Table of Contents

Advertisement

Electrode Replacement

1. Prepare the gun for service, page 32.
2. Remove the air cap and nozzle, page 34. Remove
the gun shroud (2).
3. Unscrew the electrode (7) with the multi-tool (40).
Hold the packing rod end (8h) to prevent it from turn-
ing, F
22.
IGURE
CAUTION
To avoid damaging the plastic threads, be very care-
ful when installing the electrode.
4. Apply low-strength (purple) Loctite® or equivalent
thread sealant to the electrode and packing rod
threads. Install the electrode finger-tight. Do not
overtighten.
5. Install the fluid nozzle, page 34.
6. Test gun resistance, page 26.
7. Install the gun shroud (2) and air cap, page 34.
8. Install the gun onto the manifold and bracket. See
page 33.
309297K
8h
Fig. 22. Electrode Replacement
Repair
40
TI1565A
35