10 Troubleshooting
Figure 23
Related Parameters
Table 31 Parameters related to bUS Error Auto-Reset Functionality
No.
(Addr. Hex)
F6-01
Operation Selection after
(03A2)
Communications Error
F6-14
<5>
bUS Error Auto Reset
(03BB)
F7-16
<5>
Communication Loss Timeout
(03F4)
<2> If F6-01 is set to 3, then the drive will continue to operate when a bUS error is detected. Use caution and proper safety measures, when installing
an emergency stop switch.
<5> The availability of this feature/function depends on drive model, software version and Profinet firmware version. Refer to
relating to your drive.
54
1HWZRUN
FRQQHFWLRQ
LQWHUUXSWHG
E86
&RQGLWLRQ
E86 (UURU
RQ GULYH
2XWSXW
)UHTXHQF\
Figure 24 bUS Error Delay Timing Example
Name
Determines drive response when a bUS error is detected during
communications with the option.
0: Ramp to Stop
1: Coast to Stop
2: Fast-Stop
3: Alarm Only
4: Alarm (d1-04)
5: Alarm Ramp to Stop
0: Disabled
1: Enabled
Sets the timeout value for communication loss detection in tenths of
a second.
A value of 0 disables the connection timeout.
Example: An entered value of 100 represents 10.0 seconds.
Note: A change to this parameter setting is not effective until main
power to the drive is cycled.
YASKAWA SIEP YEACOM 07A 1000-Series Option PROFINET SI-EP3 Technical Manual
E86 (UURU 'HOD\
) !  &RPP/RVV 7RXW
1HWZRUN
FRQQHFWLRQ
UHWXUQV
)
)
)
 VHF
 VHF
 VHF
Description
<2>
<5>
<5>
Default
1
0
0.0
Table 35
for specifics