PROBLEM OR SYMPTOM
Hard Water Leakage Into the Service
Lines.
CAUTION: make certain that the
water pressure is relieved from the
system before removing any dia-
phragm valve cover.
Restricted or No Service Flow
Restricted or No Drain Flow During
Backwash
Media to Service
Media to Drain
Leak From End of Pilot Body
62
Culligan® CSM Series Softeners
CHECK PROCEDURE
Loosen the tubing on the Brunermatic
bypass valve #17 Close the inlet and
outlet valves and inspect the Bruner-
matic bypass valve.
Check that valve #2 is seating.
Either valves #1 or #4 are not opening
fully. To determine which one, turn the
pilot to position #1. Observe the flow
to the drain. Rotate the pilot to posi-
tion #3 and compare the flow of water
in position #3 to the flow in position
#1. Return the pilot to H (Home).
Potentially clogged distributors or
compacted media bed.
Turn the pilot to Position #1 and then
to position #3, comparing the rate of
flow to the drain. Return the pilot to H
(Home).
Check tank distribution system
High flow of water to drain.
Air in system
Visually inspect u-cup and seals on
pilot valve spool.
CAUSE
If no flow from the tubing the pilot
strainer is probably plugged.
Seat washer may be dirty, worn or
loose.
Seat may be rough or eroded.
Diaphragm may be ruptured.
Build-up on the inside of the valve
cavity may be preventing the dia-
phragm assembly from seating in the
guide cage.
Flow should be the same for both po-
sitions but if not:
Valve #4 is not opening properly.
If backwash (position #1) is higher,
then valve #1 is not responding
properly.
Failed distributors.
Contamination of resin bed.
Flow should be the same. If not:
If the flow in position #3 is low,
see Restricted or No Service Flow
Check Procedures and causes.
Inlet water pressure may be low.
Backwash flow control may be
plugged.
If flow rate in position 3 is greater
than position 1 then valves #2 and
#5 are not functioning properly
Broken lateral
Bad distributor.
Check/replace backwash flow control
washer(s).
Brine valve did not air check, allowing
air into media tank.
Air from source other than water soft-
ener. Eliminate source or install air
vent in top of tank.
Worn or pinched u-cup or a scratch on
the pilot valve spool.
62
Cat. No. 01016370