Commissioning NC-controlled drives
6.3 Guided commissioning of SINAMICS drives
3. Select the "Select standard motor from list" option.
4. Select the motor with the "Cursor up / Cursor down" keys.
5. Press "Next step >" to enter additional motor data in the "Configuring - Motor data" dialog:
If a connected brake is detected when the unit is being configured, the system will
automatically activate the brake control and display the default setting "Motor holding brake
acc. to sequence control".
"Brake control diagnostics evaluation": For an AC drive with "Safe Brake Relay," the "Safe
Brake Control" function requires that the type of the brake control be set in parameter p1278,
to "Brake control with diagnostic evaluation" (p1278 = 0). This parameter is automatically
set for booksize components.
Information about the motor temperature sensor is provided in the FAQ
support.industry.siemens.com/cs/document/109736364).
130
CNC Commissioning: NC, PLC, Drive
Commissioning Manual, 12/2019, A5E48312804B AA
(https://