Configuring

2.1
Configuring steps
2.1.1
Procedure for configuring electrical components
Phase 1
 Siemens AG 2000. All rights reserved
SINUMERIK 840D/SIMODRIVE 611 digital Descr. of Functions HLA Module (FBHLA) – 04.00 Edition
The procedure for configuring an HLA module is divided into steps in such a
way that the user is guided through the full range of relevant settings, from the
required force, to the hydraulics components, and finally the HLA and its en-
coder evaluation circuitry. This initial configuring phase may be followed by a
second in some cases, in which the corresponding circuit recommendations
and EMC measures are taken into account.
The functions of SIMODRIVE components are described with keywords in this
Planning Guide. Limit values for functions may be specified in some cases.
For further details (e.g. characteristics), please refer to the Installation and
Start-Up Guides for SIMODRIVE 611D and SINUMERIK 840D.
Further configuring instructions and detailed ordering information can be found
in Catalogs NC 60 and NC Z.
Selection of hydrau-
lic components
Dimensioning of incom-
ing mains supply
Dimensioning of
power modules
Dimensioning of exter-
nal power supply
Dimensioning of
closed-loop control components
Fig. 2-1
Configuring steps in start-up sequence
and publication 6SN1197-0AA00
and publication 6SN1197-0AA00
Dimensioning of position
sensor (measuring system)
2
Section 2.3
and Bosch publication
Section 2.2
Section 2.2
Section 2.4
Chapter 4
Section 7.1