6 Hydraulics Diagnostics
Reaction
Remedy
To continue
program
310 709
Explanation
Reaction
Remedy
To continue
program
6-202
SINUMERIK 840D/SIMODRIVE 611 digital Descr. of Functions HLA Module (FBHLA) – 04.00 Edition
NC not ready
Channel not ready.
NC Stop in response to alarm.
NC Start disable.
The NC switches to follow-up mode.
Alarm is displayed.
Interface signals are set.
Match the number of encoder marks for the motor measuring system set in MD
5005:
ENC_RESOL_MOTOR (no. of encoder marks motor measuring system) to the
bar number of the connected encoder. (Default setting for motor measuring sys-
tem: 2 048 incr./rev).
Switch control system OFF and ON again.
Axis %1, drive %2 error in piston diameter or piston rod diameter
%1 = NC axis number
%2 = drive number
The piston diameter set in drive MD 5131:
CYLINDER_PISTON_DIAMETER is less than zero
or
the piston rod diameter set in drive MD 5132:
CYLINDER_PISTON_ROD_A_DIAMETER is greater than the piston diameter
set in drive MD 5131: CYLINDER_PISTON_DIAMETER
or
the piston rod diameter set in drive MD 5133:
CYLINDER_PISTON_ROD_B_DIAMETER is greater than the piston diameter
set in drive MD 5131: CYLINDER_PISTON_DIAMETER
NC not ready
Channel not ready.
NC Stop in response to alarm.
NC Start disable.
The NC switches to follow-up mode.
Alarm is displayed.
Interface signals are set.
Enter a valid piston diameter setting in drive MD 5131:
Enter CYLINDER_PISTON_DIAMETER (0 t D v 500 mm).
or
set the piston rod diameter in drive MD 5132:
CYLINDER_PISTON_ROD_A_DIAMETER to a lower value than the piston di-
ameter in drive MD 5131: CYLINDER_PISTON_DIAMETER.
or
set the piston rod diameter in drive MD 5133:
CYLINDER_PISTON_ROD_B_DIAMETER to a lower value than the piston di-
ameter in drive MD 5131: CYLINDER_PISTON_DIAMETER.
Switch control system OFF and ON again.
Siemens AG 2000. All rights reserved