Perkins NJ Series Troubleshooting Manual page 40

Industrial engines
Table of Contents

Advertisement

40
Troubleshooting Section
Table 31
Value
No
Yes
Logical Position
The Logical Position is the order that is required by
the user for a unique Physical Position.
Table 32
Range
1 to 16
Engine Speed (in RPM)
The "Engine Speed" is the programmed engine rpm
for a particular position of the multi-position throttle
switch.
If the ECM detects a switch combination that
has been configured as "No", a fault code will be
generated. In this situation, the ECM will ignore the
multi-position switch until the keyswitch is cycled
through OFF and ON.
Table 33
Range
Programmed Low Idle to
Programmed High Idle
Default
No
Default
1
Default
0
SENR9982-01