Troubleshooting Section
360-3
The engine has been running for at least ten
seconds.
There are no active diagnostic codes for the oil
pressure sensor or for the atmospheric pressure
sensor.
Engine oil pressure is in the "LEVEL 3" area in
Illustration 22 for four seconds.
Illustration 20
Level 1 engine oil pressure versus engine speed
Illustration 21
Level 2 engine oil pressure versus engine speed
Illustration 22
Level 3 engine oil pressure versus engine speed
System Response:
360-1
The warning lamp will flash while the warning is
active.
The Electronic Control Module (ECM) will generate a
g01269377
46 flash code that will be displayed via the diagnostic
lamp.
The ECM will generate a E360-1 event code.
The ECM will generate a SPN 100-FMI 17 event
code on the J1939 data link. The event code may be
displayed on a receiving device on the J1939 data
link.
360-2
The warning lamp will flash while the derate is active.
The ECM will generate a 46 flash code that will be
displayed via the diagnostic lamp.
The ECM will generate a E360-2 event code.
The electronic service tool will display "Engine
Derate" in the first "Engine Status" box on any status
screen.
The ECM will generate a SPN 100-FMI 18 event
g01269382
code on the J1939 data link. The event code may be
displayed on a receiving device on the J1939 data
link.
SENR9982-01