Siemens SIMATIC Ident Function Manual page 77

For moby u, moby d, rf200, rf300
Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

UDT 231: Result of MDS status (mode 3, RF200, RF300)
Table 6- 8
UDT 231: "MDS status (mode 3, RF300)"
Address
Name
0.0
+0.0
reserved0
+1.0
status_info
+2.0
UID
*0.0
+0.0
Byte_1_4
+4.0
Byte_5_8
=8.0
+10.0
MDS_type
+11.0
IC_version
+12.0
Size
+14.0
lock_state
+15.0
block_size
+16.0
nr_of_blocks
=18.0
UDT 261: Result of MDS status (mode 1, RF300)
Table 6- 9
UDT 261 "MDS status (mode 1, RF300)"
Address
Name
0.0
+0.0
reserved0
+1.0
status_info
+2.0
UID
*0.0
+0.0
Byte_1_4
+4.0
Byte_5_8
=8.0
+10.0
MDS_type
+11.0
Lock_state
FB 45 for MOBY U, MOBY D, RF200, RF300
Function Manual, 07/2012, J31069-D0166-U001-A4-7618
Type
Comment
STRUCT
BYTE
BYTE
Tag status mode
ARRAY[1...1]
STRUCT
DWORD
Tag number (unique identifier)
DWORD
END_STRUCT
BYTE
Tag type
BYTE
Chip version (for my-d = 00h)
WORD
Memory size in bytes
BYTE
Size of the user memory
BYTE
EEPROM write-protection status
BYTE
Number of blocks in user memory
END_STRUCT
Type
Comment
STRUCT
BYTE
BYTE
Tag status mode
ARRAY[1...1]
STRUCT
DWORD
Tag number (unique identifier)
DWORD
END_STRUCT
BYTE
Tag type
BYTE
EEPROM write protection status
Examples/applications
6.7 The UDTs of FB 45 / FC 45
77

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fb 45

Table of Contents