error_FB
Table 5- 3
Error code
(B#16#...)
FB 45 for MOBY U, MOBY D, RF200, RF300
Function Manual, 07/2012, J31069-D0166-U001-A4-7618
Error variable "error_FB"
00
No error; default value if everything is ok.
01
Params_DB not available in SIMATIC
02
Params_DB too small
UDT 10/11 was not used during definition
Params_DB must be 300 bytes in length (for each channel)
Check that Params_DB and Params_ADDR are correct
03
The DB after the "command_DB_number" pointer is not available in the SIMATIC.
04
"command_DB" in the SIMATIC too small
UDT 20/21 was not used during command definition
The last command in "command_DB" is a chained command; reset the chaining
bit
Check command pointer command_DB_number/command_DB_address
05
Invalid command type. You will find a description of the valid commands in the
section "RFID commands (Page 29)".
Check command pointer command_DB_number/command_DB_address
Check the current values in command_DB
Execute an init_run
06
Unexpected acknowledgement received. The parameters of the command and
acknowledgement frame do not match (command, length, address_MDS).
The user changed the command_DB_number/_address pointer during command
execution.
The user changed the command parameters in the MOBY CMD data block (UDT
20) during command execution.
Check the ASM_address and ASM_channel parameter settings. ASM_address
and ASM_channel have the same parameters for different channels.
The acknowledgement counter and command counter (see section "Cyclic
control word between master and communications module (Page 102)") between
the CM and FB are no longer synchronized
Execute an init_run
07
The MOBY_mode or MDS_control parameter (defined in UDT 10) has an illegal
value (see Section "Parameter data block").
08
A bus error has occurred which is reported by system functions SFB 52/53. More
information on this error is available in the error_BUS variable.
ASM_address or ASM_channel not available
Execute an init_run