The following voltages and waveforms should be adjusted in the order they are presented.
Always adjust the DC levels before the waveform adjustments to most accurately set the Plasma
Display Panel.
VSC Control VR3 110 Volts used to shape the Y Drive waveform by setting the V Scan level.
Measured at the VSC test points R60 and Floating Ground.
-VY Control VR4 - 65 Volts used to shape the Y Drive waveform by setting the negative
excursion of the Drive Signal.
Plasma Display Panel Troubleshooting - 2007
60PC1D
Panel Adjustments
3 Voltmeter Adjustments to Y SUS
Measured at (left side) of Resistor R181 to Chassis Ground.
Check VSC
Y SUS Board
50
Troubleshooting
Check -VY
Meter Adjustments continued on next page