60" X-PSU. Adjustment Points and Distribution of Connectors
VR951 - VS ADJ
P812
10
VS SUPPLY (190V-ADJ)
VS SUPPLY (190V-ADJ)
9
8
VS SUPPLY (190V-ADJ)
7
N.C.
6
GROUND
5
GROUND
4
GROUND
3
GROUND
VA SUPPLY (60V-ADJ)
2
1
VA SUPPLY (60V-ADJ)
P811
1
5V SUPPLY
2
5V SUPPLY
3
GROUND
4
GROUND
P800
13
3.3V_ON_IN
12
N.C.
11
6V
10
N.C.
9
GROUND
8
STBY5V
7
5V_ON_IN
6
5V
5
VS_ON_IN
4
GROUND
3
STBY5V
2
RL_ON
1
AC_ON
Plasma Display Panel Troubleshooting - 2007
X-PSU Main Part (LGE No: EAY32961801)
VA & VS-ADJ have been
adjusted against PDP
Module Specifications
during final assembly
process in Plasma TVs'
Factory
VR901 - VA ADJ