Siemens SIMATIC NET SCALANCE XR-300M EEC Series Compact Operating Instructions page 53

Industrial ethernet switch
Table of Contents

Advertisement

F1
Figure 6-3
● If the power supply fails at pins L1/M1, this is indicated by LED L1.
● If the power supply fails at pins L2/M2, this is indicated by LED L2.
Connecting a redundant power supply to 2 power supply units
To connect the power supplies, use pins L1/M1 of the left terminal block "PS1" and pins L2/M2
of the right terminal block "PS2".
F1
Figure 6-4
● If the power supply fails at pins L1/M1, this is indicated by LED L1.
● If the power supply fails at pins L2/M2, this is indicated by LED L2.
It would also be possible to use the L1/M1 pins of the right terminal block. In this case, however,
identification of the terminal block involved from the LED display is not immediately obvious.
SCALANCE XR-300M EEC
Compact Operating Instructions, 11/2019, A5E02661176-14
L1 L2
L1 L2
F2
L1 M1
L1 M1
M2
M2
L2
L2
PS1
Assignment of the LED display to the pins for redundant power supply with devices with two
power supply units
L1 L2
L1 L2
F2
L1 M1
L1 M1
M2
M2
L2
L2
PS1
Assignment of the LED display to the pins for redundant power supply with devices with two
power supply units.
F1
F2
L1 M1
L1 M1
M2
M2
PS2
F1
F2
L1 M1
L1 M1
M2
M2
PS2
Connecting
6.7 Power supply
L2
L2
L2
L2
53

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic net scalance xr324-4m eec

Table of Contents