Maintenance

Draining heat pump on the secondary side

1. Close the on-site boiler drain & fill valve.
Checking the temperature sensors
For sensor connections to the controller and sensor
PCB: See page 27.
For the position of the sensors in the heat pump: See
Fig. 50 on page 67.
Sensor
Outside temperature sensor (F0)
Buffer temperature sensor (F4)
Cylinder temperature sensor, top (F6)
Cylinder temperature sensor, bottom (F7)
Flow temperature sensor, heating circuit with mixer M2/HC2 (F12)
System flow temperature sensor (F13)
Cooling circuit flow temperature sensor (heating circuit without mixer A1/HC1 or sepa-
rate cooling circuit SKK) (F14)
Room temperature sensor for separate cooling circuit (F16)
Boiler water temperature sensor, external heat generator (F20)
Room temperature sensors
Sensors in the refrigerant circuit
Secondary circuit flow temperature sensor (F8)
Return temperature, secondary circuit (X25.11/X25.12)
Air intake temperature sensor (X25.1/X25.2)
Air discharge temperature sensor (X25.3/X25.4)
68
2. Drain the heat pump at the drain valve: See Fig. 50
on page 67.
Test element
NTC 10 k
Ω
Pt500A