Location
• The installation conditions, concerning protection against overheating of the surfaces adjacent to the cooker,
must conform to Fig.3a or 3b.
• The appliance must be kept no less than 200 mm away from any side wall which exceeds the height of the hob
surface (Fig. 3a or 3b).
• The appliance must be housed in heat resistant units.
https://producthelp.fisherpaykel.com/eu/Cook/Freestanding_Cookers/Dual_Fuel/OR120DDWGX2/User_Guide_OR120DDWG...
Fig 1
Updated: Fri, 07 Feb 2020 03:46:13 GMT
Powered by
1

Advertisement

Table of Contents
loading

Summary of Contents for Fisher & Paykel OR120DDWGX2

  • Page 1: Installation Instructions

    • The appliance must be kept no less than 200 mm away from any side wall which exceeds the height of the hob surface (Fig. 3a or 3b). • The appliance must be housed in heat resistant units. https://producthelp.fisherpaykel.com/eu/Cook/Freestanding_Cookers/Dual_Fuel/OR120DDWGX2/User_Guide_OR120DDWG… Updated: Fri, 07 Feb 2020 03:46:13 GMT Powered by...
  • Page 2: Assembling The Backguard

    • If the cooker is located on a pedestal, provide safety measures to prevent it falling out. Assembling the Backguard Installing the backguard is MANDATORY. Fig 2 • Assemble the backguard as shown in Fig. 2 and fix it by screwing the five screws “A”. https://producthelp.fisherpaykel.com/eu/Cook/Freestanding_Cookers/Dual_Fuel/OR120DDWGX2/User_Guide_OR120DDWG… Updated: Fri, 07 Feb 2020 03:46:13 GMT Powered by...
  • Page 3 Fig 3a Class 1 Gas connection made using rubber hose which must be visible and easily inspected or using rigid or flexible metal pipe. https://producthelp.fisherpaykel.com/eu/Cook/Freestanding_Cookers/Dual_Fuel/OR120DDWGX2/User_Guide_OR120DDWG… Updated: Fri, 07 Feb 2020 03:46:13 GMT Powered by...
  • Page 4 Fig 3b Class 2 Subclass 1 Gas connection made using rigid or flexible metal pipe. https://producthelp.fisherpaykel.com/eu/Cook/Freestanding_Cookers/Dual_Fuel/OR120DDWGX2/User_Guide_OR120DDWG… Updated: Fri, 07 Feb 2020 03:46:13 GMT Powered by...
  • Page 5: Leveling The Cooker

    The cooker is already fitted with six levelling feet. Level the cooker by screwing or unscrewing the feet (Fig. 4d). Make sure you follow the instructions in Figs. 4a, 4b, and 4c. Bolts are supplied with the cooker in a separate kit. https://producthelp.fisherpaykel.com/eu/Cook/Freestanding_Cookers/Dual_Fuel/OR120DDWGX2/User_Guide_OR120DDWG… Updated: Fri, 07 Feb 2020 03:46:13 GMT Powered by...
  • Page 6: Moving The Cooker

    • Two people must always raise the cooker, as shown, to prevent damaging the adjustable feet. • Do not lift the cooker by the door handles. • DO NOT DRAG the cooker. Lift the feet clear of the floor. https://producthelp.fisherpaykel.com/eu/Cook/Freestanding_Cookers/Dual_Fuel/OR120DDWGX2/User_Guide_OR120DDWG… Updated: Fri, 07 Feb 2020 03:46:13 GMT Powered by...
  • Page 7 Ventilation Requirements (GB & IE Only) Fig. 5b Incorrectly moving the cooker Fig. 5a Correctly raising the cooker Fig. 5c Incorrectly raising the cooker https://producthelp.fisherpaykel.com/eu/Cook/Freestanding_Cookers/Dual_Fuel/OR120DDWGX2/User_Guide_OR120DDWG… Updated: Fri, 07 Feb 2020 03:46:13 GMT Powered by...
  • Page 8 • Building Regulations • British Standards • Regulations for Electrical Installation Failure to install the appliance correctly could invalidate any manufacturer’s warranty and lead to prosecution under the above-quoted regulation. https://producthelp.fisherpaykel.com/eu/Cook/Freestanding_Cookers/Dual_Fuel/OR120DDWGX2/User_Guide_OR120DDWG… Updated: Fri, 07 Feb 2020 03:46:13 GMT Powered by...
  • Page 9: Gas Connection

    Only a suitably qualified and registered person may convert the appliance to a different gas type. • When using Butane gas a supply pressure of 28 -30 mbar is required. • When using Propane gas a supply pressure of 37 mbar is required. https://producthelp.fisherpaykel.com/eu/Cook/Freestanding_Cookers/Dual_Fuel/OR120DDWGX2/User_Guide_OR120DDWG… Updated: Fri, 07 Feb 2020 03:46:13 GMT Powered by...
  • Page 10: To Connect The Gas Supply

    The presence of bubbles will indicate a leak. If there is a leak, tighten the fitting and then recheck for leaks. Fig 6a Do not use a naked flame to test for leaks. https://producthelp.fisherpaykel.com/eu/Cook/Freestanding_Cookers/Dual_Fuel/OR120DDWGX2/User_Guide_OR120DDWG… Updated: Fri, 07 Feb 2020 03:46:13 GMT Powered by...
  • Page 11 • Pull the feeder cable and block it with the cable clamp “D”. • Re-mount shield “A”. The earth conductor must be left about 30 mm longer than the others. https://producthelp.fisherpaykel.com/eu/Cook/Freestanding_Cookers/Dual_Fuel/OR120DDWGX2/User_Guide_OR120DDWG… Updated: Fri, 07 Feb 2020 03:46:13 GMT Powered by...
  • Page 12 Fig 7a Fig 7b Power Supply 230V~ 5300W 50Hz Feeder Cable Section “TYPE H05RR-F” 230V~ 3 x 2.5 mm (**) (**) - Connection with wall box connection. Fig 7 c https://producthelp.fisherpaykel.com/eu/Cook/Freestanding_Cookers/Dual_Fuel/OR120DDWGX2/User_Guide_OR120DDWG… Updated: Fri, 07 Feb 2020 03:46:13 GMT Powered by...
  • Page 13 Updated: Fri, 07 Feb 2020 03:46:13 GMT Powered by...