Electronic Handwheel (Optional); Cable Preparation - Baldor DBSC 100 Series Installation And Operating Manual

Hide thumbs Also See for DBSC 100 Series:
Table of Contents

Advertisement

Section
The electronic handwheel (pulse follower) is an optional connection that allows
The electronic handwheel (pulse follower) is an optional connection that allows
the control to follow the pulses from an encoder input. This is a factory installed
the control to follow the pulses from an encoder input. This is a factory installed
option and must be ordered with the control. This wiring must be separated
option and must be ordered with the control. This wiring must be separated
from power wiring. Separate encoder cable by at least 3" from parallel runs of
from power wiring. Separate encoder cable by at least 3ʺ from parallel runs of
power wires. Cross power wires at right angles only.
power wires. Cross power wires at right angles only.

Cable Preparation

Cable Preparation
Encoder wiring must be shielded twisted pairs, #22 AWG (0.34mm2) minimum
Encoder wiring must be shielded twisted pairs, #22 AWG (0.34mm
size, 200' (61m) maximum, with an insulated overall shield.
size, 200ʹ (61m) maximum, with an insulated overall shield.
DBSC Control End (See Figure 3-10.)
DBSC Control End (See Figure 3-10.)
1. S t r i p the outside jacket approximately 0.375" (9.5mm) from the end.
1.
Strip the outside jacket approximately 0.375ʺ (9.5mm) from the end.
2. S o l d e r a #22 AWG (0.34mm2) wire to the braided shield. Carol cable has
2.
Solder a #22 AWG (0.34mm
a clear Mylar sleeve between the braided shield and the wire bundle.
a clear Mylar sleeve between the braided shield and the wire bundle.
Belden cable does not have a Mylar sleeve.
Belden cable does not have a Mylar sleeve.
3. C o n n e c t all shields to X9-13. To do this, solder a "Drain Wire" from each
3.
Connect all shields to X9-13. To do this, solder a "Drain Wire" from each
shield to the wire soldered to the braided shield in step 2.
shield to the wire soldered to the braided shield in step 2.
4. Insulate or tape off ungrounded end of shields to prevent contact with other
4.
Insulate or tape off ungrounded end of shields to prevent contact with other
conductors or ground.
conductors or ground.
Encoder End
Encoder End
1. S t r i p the outside jacket approximately 0.375" (9.5mm) from the end.
1.
Strip the outside jacket approximately 0.375ʺ (9.5mm) from the end.
2. I d e n t i f y each of the four twisted pair and label or use the color codes
2.
Identify each of the four twisted pair and label or use the color codes
shown in Figure 3-10.
shown in Figure 3-10.
3. Insulate or tape off ungrounded end of shields and unused conductors to
3.
Insulate or tape off ungrounded end of shields and unused conductors to
prevent contact with other conductors or ground.
prevent contact with other conductors or ground.
CAUTION: D o not connect any shields to the encoder case or motor
CAUTION: Do not connect any shields to the encoder case or motor
MN1229
MN1229
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Electronic Handwheel (Optional)

Electronic Handwheel (Optional)
2
frame. Do not connect any shields to ground or another
frame. Do not connect any shields to ground or another
power supply or damage to the control may result.
power supply or damage to the control may result.
3
) wire to the braided shield. Carol cable has
-
1
2
) minimum
3
3–13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dbsc 102Dbsc 105