IS 3180 (Fig� 5�10)
Mounting
20 m lens
height
Setting level tangential
1.5 m
8
5 m
6 m
7 m
8 m
20
12 m
2.0 m
8
5 m
6 m
7 m
10 m
20
20 m
2.5 m
8
6 m
8 m
10 m
13 m
20
20 m
3.0 m
8
8 m
9 m
12 m
17 m
20
20 m
• Insert fastening screw and mount load module
• Fit sensor and load module together and screw into place
• Switch ON power supply
• Set functions. (➔ "6� Function")
• Fit decorative trim panel.
6� Function / operation
Factory settings
Twilight level: 1000 lux
Time setting: 5 s
Twilight setting (Fig� 6�1)
The chosen sensor response threshold is infinitely adjustable from approx. 2-1000 lux.
Control dial
means twilight mode at approx. 2 lux.
Control dial
means daylight operation / independent of ambient light level.
Teach mode
The control must be set to
at the level of light at which you want the sensor to
respond to movement from now on. The level of ambient brightness measured in this
way will be saved after 10 seconds.
8 m lens
radial
Setting level tangential
2.5 m
4
3 m
2.0 m
2.5 m
5 m
2.5 m
3.0 m
6 m
3.0 m
3.0 m
7 m
3.0 m
4.5 m
8
9 m
3.5 m
2.5 m
4
4 m
3.0 m
3.0 m
5 m
3.0 m
3.5 m
6 m
3.0 m
4.0 m
8 m
3.0 m
4.5 m
8
8 m
3.5 m
3.0 m
4
5 m
3.0 m
4.0 m
7 m
3.5 m
5.0 m
8 m
3.5 m
5.0 m
9 m
4.0 m
4.0 m
8
10 m
3.5 m
4.0 m
4
5 m
3.0 m
4.5 m
6 m
3.0 m
5.0 m
8 m
4.0 m
4.0 m
10 m
4.5 m
4.0 m
8
13 m
5.5 m
30
Dazzle guard
This product is equipped with an integrated dazzle guard. If blinded by extraneous
light, this puts the sensor into a brightness-related evaluation mode for 60 s. (see
radial
Troubleshooting).
Time setting (Fig� 6�1)
The time you want the connected lamp to stay ON for is infinitely adjustable between
approx. 5 sec to a maximum of 15 min. Any movement detected before this time
elapses will restart the timer.
Pulse function
The pulse function activates the output for 2 s (e.g. for staircase lighting time switches).
Manual override function (Fig� 4�1)
If a mains switch is installed in the mains supply lead, the following functions are
available in addition to simply switching ON and OFF:
Important: The switch should be actuated in rapid
succession (in the 0.5 - 1 s range).
Sensor mode
1) Switch light ON (when light is OFF): switch ON and OFF once.
Sensor stays ON for the period selected.
2) Switch light OFF (when light is ON): switch ON and OFF once.
Sensor goes out or switches to sensor mode.
Manual override
1) Activate manual override:
Switch ON and OFF twice. The sensor is set to stay ON for 4 hours (red LED lights
up behind the lens). Then it returns automatically to sensor mode (red LED OFF).
2) Deactivate manual override:
Switch ON and OFF once. Sensor goes out or switches to sensor mode.
7� Accessories (optional)
User remote control RC5 EAN 40078141 559410
Additional functions, RC5
– Light ON/OFF 4 h
– User reset
– 100 h burn in