Replacing The Intrusion Switch - Fujitsu PRIMERGY Econel 200 S2 Service Supplement Manual

Hide thumbs Also See for PRIMERGY Econel 200 S2:
Table of Contents

Advertisement

Replacement routines
4.6

Replacing the intrusion switch

Part number: A3C40082393
The intrusion switch monitors the removing of the side cover of the housing.
Ê Remove the side cover as described in section "Preparation" on page 17.
Ê Remove the processor fan 2 as described in section "Removing the
processor fan 2" on page 17.
Figure 13: Removing the intrusion switch
Ê Press sideward on the hooks of the intrusion switch holder and pull down the
holder.
Ê Disconnect the cable from the system board (connector Intrusion, see
system board foil D2530).
Ê Release the cable from the cable clamps, pull it through the recesses of the
chassis.
Ê Connect the cable to the system board (connector Intrusion, see system
board foil D2530).
Ê Route the new cable as the old one.
Econel 200 S2
Replacing the intrusion switch
Service Supplement
29

Advertisement

Table of Contents
loading

Table of Contents