Parameter Settings - Baxi Luna 3 Silver Space Series Operating & Installation Instructions Manual

High efficiency wall-mounted gas-fired boilers for external use
Table of Contents

Advertisement

Available languages

Available languages

To set the boiler parameters, proceed as follows:
• press and hold down IP for at least three seconds;
• press and hold down
and then press
When the function is active on the display, the message "F01" appears together with the value of the
selected parameter.
Change parameters
• To scroll the parameters press
• To modify individual parameters press
N.B.: the value is automatically memorised after approximately 3 seconds. (Do not press any buttons until the setting begins to flash).
Description of parameters
Type of boiler
F01
10 = sealed chamber - 20 = open chamber
Type of gas
F02
00 = NATURAL GAS - 01 = LPG
Hydraulic system
00 = instantaneous appliance
F03
05 = appliance with external storage boiler
08 = appliance for heating only
Programmable relay 1 setting
F04
(See SERVICE instructions)
02 = zone system
Programmable relay 2 setting
F05
13: "cool" function for external air-conditioning system
(See SERVICE instructions)
External sensor input setting
F06
(See SERVICE instructions)
Auxiliary input configuration
F07
(See SERVICE instructions)
F08...F12
Manufacturer information
F13
CH max. heat output (0-100%)
F14
DHW max. heat output (0-100%)
F15
CH min. heat outpu (0-100%)
F16
Maximum temperature setpoint (°C) setting
0 0 = 85°C - 01 = 45°C
F17
Pump overrun time in CH mode
(01-240 minutes)
F18
Burner ignition delay in CH mode
(00-10 minutes) - 00=10 seconds
F19
Manufacturer information
F20
Manufacturer information
F21
anti-legionellosis function
00 = Disabled - 01 = Enabled
F22
Manufacturer information
F23
Maximum DHW temperature setpoint (ACS)
F24
Manufacturer information
F25
No water safety device
F26...F29
Manufacturer information (read-only parameters)
F30
Manufacturer information
F31
Manufacturer information
F32...F41
Diagnostics (See SERVICE instructions)
Final
Enable calibration function (See SERVICE instructions)
parameter
Caution: do not change the "manufacturer information" parameters
INSTRUCTIONS FOR FITTERS

22. PARAMETER SETTINGS

(see figure to side).
+/-
;
+/-
;
Factory setting
250 Fi
".
72
310 Fi
10
00 or 01
00
02
03
00
02
00
100
100
00
00
03
03
07
--
00
00
60
35
00
--
10
30
--
0
925.523.1 - EN