Routine Maintenance Instructions - Baxi Luna 3 Silver Space Series Operating & Installation Instructions Manual

High efficiency wall-mounted gas-fired boilers for external use
Table of Contents

Advertisement

Available languages

Available languages

BLOCK
Block errors are signalled on the display with
and a flashing >>>OK message alternating (about
every 2 seconds) with the flashing message <ER-
ROR>.
The block is identified by an error code followed by
the letter E.
Press OK to reset the electronic board and resume
operation.
The display shows <RESET> and then >>>OK.
CODE
01E
Ignition failure
02E
Safety thermostat tripped
03E
Flue thermostat/ flue pressure switch tripped
04E
Safety error due to frequent flame loss
05E
Delivery sensor fault
06E
DHW sensor fault
10E
Hydraulic pressure switch block
Safety thermostat for low temperature system cuts
11E
in (if connected)
18E
System water filling in progress
19E
System filling fault
25E
Pump faulty or air in system
Communication error between electronic board and
31E
remote control unit
35E
Parasite flame (flamer error)
80E
Internal error in remote control unit
96E
Internal error in remote control unit
97E
Electronic board input frequency (Hz) incorrectly set Change the frequency (Hz) setting.
98E
Internal card error
99E
Internal card error

10. ROUTINE MAINTENANCE INSTRUCTIONS

To keep the boiler efficient and safe, have it checked by the authorised Service Centre at the end of every operating period.
Careful servicing ensures economical operation of the system.
Do not clean the outer casing of the appliance with abrasive, aggressive and/or easily flammable cleaners (e.g.: petrol, alcohol, and
so on). Always switch off the appliance before cleaning it (see section 6 "Switching off the boiler").
INSTRUCTIONS FOR USERS
ERROR
54
CORRECTIVE ACTION
Press OK. If this fault persists, call the Authorised Service Centre.
Press OK. If this fault persists, call the Authorised Service Centre.
Call the Authorised Service Centre.
Call the Authorised Service Centre.
Call the Authorised Service Centre.
Call the Authorised Service Centre.
Check that the pressure in the system is correct; See section 5.
If this fault persists, call the Authorised Service Centre.
Call the Authorised Service Centre.
Wait for filling to finish.
Call the Authorised Service Centre.
Call the Authorised Service Centre
Press OK. If this fault persists, call the Authorised Service Centre.
Press OK. If this fault persists, call the Authorised Service Centre.
Call the Authorised Service Centre.
Call the Authorised Service Centre.
Call the Authorised Service Centre.
Call the Authorised Service Centre.
925.523.1 - EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Luna 3 silver space 310 fiLuna 3 silver space 250 fi

Table of Contents