Installation of Indoor, Outdoor Unit

Read completely, then follow step by step.

Select the best location

1. Indoor unit
Wall mounted Type
• Do not have any heat or steam near the unit.
• Select a place where there are no obstacles in
front of the unit.
• Make sure that condensation drainage can be
conveniently routed away.
• Do not install near a doorway.
• Ensure the spaces indicated by arrows from
the wall, ceiling, fence or other obstacles.
• Use a stud finder to locate studs to prevent
unnecessary damage to the wall.
CAUTION: Install the indoor unit
on the wall where the height from
the floors more than 2.3 meters.
Duct Type
Install the air conditioner in the location that
satisfies the following conditions.
• The place shall easily bear a load exceeding
four times the indoor unitʼs weight.
• The place shall be able to inspect the unit as
the figure.
• The place where the unit shall beleveled.
• The place shall allow easy water
drainage.(Suitable dimension "H" is necessary
to get a slope to drain as figure.)
• The place shall easily connect with the
outdoor unit.
• The place where the unit is not affected by an
electrical noise.
• The place where air circulation in the room will
be good .
• There should not be any heat source or steam
near the unit
Installation of Indoor, Outdoor Unit
More than
10 cm
More than 2.3 m
More than 10 cm
More than 2.3 m
Top view
Inspection Hole
(unit: mm)
(600X600)
Control box
Front view
More than 20 cm
More than
10 cm
More than 20 cm
More than
10 cm
600
Front
600
H
Inspection Hole
(600X600)
Installation Manual 7