Optional Operation - Duct Type; Group Control - LG L5UC728FA0 Installation Manual

Table of Contents

Advertisement

Optional Operation - Duct Types

Group Control

It operates maximum 16 Units by only one Wired Remote Controller,
and each Unit starts sequentially to prevent overcurrent.
Terminal(Local Supply)
Block
RED(12V)
YL(SIGNAL)
BR(GND)
AUTO SWING
OPERATION
SET TEMP
FAN SPEED
SUB FUNCTION
Room Temp
HI
AUTO
Heater
Preheat
MED
JET
Defrost
Humidify
LO
Filter
Out door
Time
ZONE
1 2 3 4
Timer
Operation unit
Program set
On
Off
Set no. Time
01
03
05
07
09
11
13
15
17
19
21
23
Slide Switch2
Two Thermistor system
• Open the rear cover of Remote Controller to
set up the mode.
• Selectable options are three as follows.
- Remo: Sensing the room Temperature.
- Indoor Unit: Sensing the intake air into
indoor Unit.
- 2 TH: Sensing the lower temperature of the
two thermistors.
• To set up the mode, adjust the slide switch to
desired mode position on installing.
Indoor Unit 1
Terminal(Local Supply)
Block
Connector
RED(12V)
Main PCB
YL(SIGNAL)
YL(SIGNAL)
#1
BR(GND)
BR(GND)
Wired Remote Controller
(Standard)
Single
Group
Remote�
Controller�
PCB
Optional Operation - Duct Types
Main PCB
Indoor Unit 2
Connector
Main PCB
....
YL(SIGNAL)
YL(SIGNAL)
#2
BR(GND)
BR(GND)
Connecting Cable(Local Supply)
....
• Using the supplied Wired Remote Controller,
wire them like above.
• Move slide switch 2 to "Group" position.
• Ensure that the color of wire.
Slide Switch1
Slide Switch2
Indoor Unit 16
Terminal(Local Supply)
Block
Connector
Main PCB
YL(SIGNAL)
#16
BR(GND)
Room Temp. Sensing
Remo.
Indoor Unit
2 TH(Remo.+Indoor)
Single
Group
CAUTION
• On installing, don't impact to the PCB
and LCD display.
• Don't remove the protection sheet.
• Use the specified screw.
• On installing, turn off the main power.
Installation Manual 49

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents