Installation of Indoor, Outdoor Unit
Installation of Indoor, Outdoor Unit
Read completely, then follow step by step.
Select the best location
Indoor unit
1. Do not have any heat or steam near the unit.
2. Select a place where there are no obstacles
in front of the unit.
3. Make sure that condensation drainage can be
conveniently routed away.
4. Do not install near a doorway.
5. Ensure the unit is unobstructed, allow proper
space on all sides according to the arrows
and distance measurements in the figures.
6. Use a Metal Detector or Metal Scanner to
locate studs to prevent unnecessary damage
to the wall.
[Cealing Concealed Duct Type]
Top view
600(23 19/32)
Front
Front view
Capacity(Btu/h class)
9/12k
600(23 5/8)
18k
600(23 5/8)
8 Multi Air Conditioner
600(23 19/32)
7 5/16
H=13/16 or more
A
B
A
B
900(35 15/32)
1100(43 5/16)
[Standard /Artcool Mirror Type]
More than
100(3 15/16)
More than
2300(90 9/16)
[Cealing Cassette Type]
20(13/16) or more
Ceiling
False ceiling
1500(59 1/16)or
more
More than 200(7 7/8)
More than
100(3 15/16)
Unit:mm(inch)
False ceiling
1500(59 1/16) or
more
Floor
Unit:mm(inch)