temperature is lower than 75°C, the function can not be recovered. It has to cut off the power supply, connect to the
power supply again, then it can be used normally.
7. Temperature sensor error detect
Cut off: Two digital tubes show E0 and flash.The beeper alarms, function can not be open. Clear the error then it can be
used normally.
Short cut: Two digital tube shows E1 and flash. The beeper alarms. All function can not be opened. Clear the error then it
can be used normally.
Warnings
1. Safety precautions
a. To avoid fire, do not dry clothes or leave any towels in the sauna.
b. To prevent burns or electric shocks, do not touch or use metal tools on the net cover of the far infrared film
elements.
c. While in the sauna, do not touch the light bulb. If the bulb needs to be changed, switch it off and wait until the
sauna is shut off and the bulb is cool
d. Do not spray water on the far-infrared tube. This activity may result in electric shock or damage to the heater
elements.
e. Do not use the infrared sauna if you have any of the following conditions:
1. Open wounds
2. Eye diseases
3. Sever sunburns
4. Elderly & weak people, especially those suffering from a disease, pregnant women and infants are
prohibited. Children over the age of 6 years may use the sauna under the supervision of adults.
5. If suffering from a disease directly related to temperature, seek the advice of a doctor before using.
6. Do not place pets in the sauna.
7. Do not use the sauna if you are under the effects of alcohol.
Trouble Shooting:
problem
1
indicator light for power
supply not working
2
Indicator light for function
possible reason
The connector is not connected
properly
No power supply input
Indicator light is broken
The heating indicator light is broken
11
countermeasure
Check the connector or replace a new
one
chick the circuitry ( especially weather
there is power supply input)
replace the circuitry panel
Replace the relevant control panel