Trouble Shooting:
problem
1
indicator light for power
supply not working
2
Indicator light for function
is not working
3
Infrared Heater not
heating up
4
Odor from the sauna
5
Light bulb is not working
6
Sauna is not power up
7
The temperature display
show "EP"
8
The temperature display
show "H"
possible reason
The connector is not connected
properly
No power supply input
Indicator light is broken
The heating indicator light is broken
The circuit board or components are
broken
the temperature sensor is broken
The heater is broken
The wire junction or the heater's wire
is loosen
the temperature sensor is broken
the circuit board of the relay is not
work
The circuit's problems
Light bulb is burned out
Light bulb wiring is loosen
Problems with electrical control panel
Power cord is unplug
Outlet has no power
Power supply or circuit panel is
broken
The connector of temperature sensor
is loose or sensor damaged
The temperature inside the sauna
room is too high
10
countermeasure
Check the connector or replace a new
one
chick the circuitry ( especially weather
there is power supply input)
replace the circuitry panel
Replace the relevant control panel
Replace the circuit board
check the connect is loosen and
replace it
Replace with a new one
Of the same specifications
Check and make them tight
check junction of the temperature
sensor is loosen and replace it
replace the circuit board
1) there is eyewinker around, remove
it
2)some heater's temperature over
high,cut off the power supply,replace
it
3) parts on the circurity is broken
Replace the light bulb
Replace the lamp holder
Repair or replace it
Plug back power cord to outlet
Check outlet or circuit breaker
Replace the power supply or related
circuitry board
Tighten the connector of temperature
sensor or change to a new
temperature sensor.
Turn off the unit, and contact the
manufacture.
EN