Spool Gun Options; Spool Gun Pulse - Lincoln Electric Ranger 330MPX Operator's Manual

Hide thumbs Also See for Ranger 330MPX:
Table of Contents

Advertisement

RANGER
®
330MPX

SPOOL guN OPTIONS

Synergic Control
The spool gun may be set in either "normal" control or "synergic"
control. Synergic mode automatically adjusts the voltage when
the wire feed speed is changed.
To activate synergic control, press the
knob for options when in the spool gun
mode. Rotate the knob to choose
"Synergic Control" and then press the
knob.
Remote
Synergic
Pulse
Spot Time
Control
Control
Range
10-22
Press knob to select
?

SPOOL guN PuLSE

Spool Gun Pulse is only available when an
aluminum wire is selected with the
Ready.Set.Weld menu
Activating Spool Gun Pulse toggles both the
voltage and wire feed speed between a peak and
a low level. It is useful for lower heat input
welding and creating the appearance of "stacked
dimes" in aluminum.
To activate spool gun pulse, the Ready.Set.Weld
entry must be set for an aluminum electrode.
Press the knob for options when in the spool gun
mode. Rotate the knob to choose "Pulse" and
then press the knob. Adjust the pulse frequency
from OFF to 2.5 Hz.
The voltage and wire feed speed values represent
peak values. The lower settings are automatically
calculated based upon the Ready.Set.Weld entries.
Rotate the knob to change between
normal control and synergic control.
Press the knob to select
Voltage
Synergic
Control
Normal
Control
Wire feed speed
Press knob to select
?
Remote
Synergic
Pulse
Spot Time
Control
Control
Range
10-22
Press knob to select
?
B-9
OPERATION
Arc Length
Synergic
Control
Normal
Control
Deposition Rate
Press knob to select
?
Pulse
0.2
Hertz
Press knob to select
?

Hide quick links:

Advertisement

Table of Contents
loading