Spool Gun Calibration - Lincoln Electric Ranger 330MPX Operator's Manual

Hide thumbs Also See for Ranger 330MPX:
Table of Contents

Advertisement

RANGER
®
330MPX

Spool Gun Calibration

Spool gun calibration should be run when a new spool gun is
attached to the Ranger. The calibration helps to compensate for
differences between guns and will make the wire feed speed
readings more accurate.
To calibrate a spool gun, start by loading
the desired wire into the spool gun. Feed
wire out of the gun and then trim it flush
with the contact tip. Press the knob to
continue.
Load wire into the spool gun. Trim the
wire flush with the contact tip.
Press knob to continue
?
Rotate the knob to adjust the value shown
on the screen to match the actual
measured length of wire. Press the knob
to complete spool gun calibration.
Feeding wire...
21.7
inches
Press knob to continue
?
The calibration process will feed wire out of
the spool gun for several seconds. Press the
knob to start the wire feeding.
Caution! Wire will feed out of spool
gun during calibration.
Press knob to continue
B-19
The screen will show wire feeding from the
spool gun for about 5 seconds.
Feeding wire...
?
OPERATION
Press knob to continue
?