Control Panel Features

Power On and Off

You can turn the power on and off by touching the power button on the heating unit. The default
temperature is 95°F(35°C) on both sides. It will change and display the current temperature immediately.
When power is turned off and restarted, the temperature is automatically set to the previous operating
temperature.

Setting the Temperature

The heating temperature can be set between 82°F(28°C) through 113°F(45°C). The queen and
king sizes are equipped with dual heating function which can set the left and right temperatures
independently. When setting the temperature above 100°F(38°C), the high temperature entry
mode is applied for safety and the high temperature warning lamp will be lit.
Setting the left and right temperatures
The left and right temperature of the pad can be set in 1°F increments with the "+/-" buttons on the
left/right display screen. When the desired temperature is displayed on the screen, setting will be
completed after 3 seconds.
Single size do not have dual heating mode.
Dual left/right heating is recommended to be used at
Setting temperatures over 100°F(38°C)
When the "+" button is pressed to set the temperature above 99°F(37°C), "
Release the button and wait for a brief moment, the "
caution lamp will blink. (For about 1.5 seconds)
Pressing the + after the brief moment will allow the temperature to be set above 100°F(38°C).
If you touch + button again, you can set a high temperature over 100°F(38°C).
Turning off heating on one side
Touch the "-" to reduce the temperature past 82°F(28°C) and " " will be displayed on the screen.
For single size
The current temperature is displayed on the left of the display window, and the set temperature is
displayed on the right.
Power saving mode
If the heating unit has not been operated for 30 seconds, it goes into step 1 power saving mode.
(Screen brightness decreases)If the power saving mode is maintained for more than 1 minute,
the power saving mode is entered in step 2 and the "Operation indicator" icon is displayed to
indicate normal operation. This indicator icon will display for sides that are being heated. If only
one side is being heated, the indicator icon will only be displayed on that one side. To resume
control of the heating unit, touch any button to exit power saving mode.
95°F(35°C)
or higher.
" indicator and the high temperature
" will be displayed.