5. Inspection
5-3.
Inspection and Factory Settings
Sequence
Item
1
External visual
check
2
Power switch
Auto mode
check
LCD-ON
EVF-ON
3
Zoom operation
Auto mode
check
LCD-ON
4
Shock noise check
Auto mode
in Auto mode
LCD-ON
5
Resolution check
Auto mode
Focusing check
LCD-ON
5-2
Preparations for adjustment
Mode
(measurement points, subject, other)
(1) Observe the camera.
(1) Plug the DC COUPLER CP-04 into
the camera and connect the AC-5V.
(2) Insert a SD card.
(3) Select the mode dial setting.
(4) Set the power switch to ON.
(5) If a message appears asking for the
language and date to be set, press
the specification button on the right.
(6) Check the LCD screen display
status.
(7) Press the <EVF/LCD> button.
(8) Check for blemishes in the CCD live
image.
(1) Zoom drive noise.
(2) LCD screen.
(3) Zoom operation (T <-> W).
(1) Apply a shock to the camera using
the shock jig.
(1) Use a macro resolution chart as the
subject.
(2) Set the camera to Macro mode.
(3) Set the camera up so that the chart
fills the screen from corner to corner.
(4) Press the shutter button to take a
picture.
Confidential: FUJIFILM Service Center Use Only
FinePix S1500 Service Manual
Method of adjustment
(VRs, waveforms, required values)
(1) Check for damage to the outer
casing (Inventory repairs only).
Check for problems with the clicking
or sliding movement of switches.
Check for dust or fogging in the
Finder.
Check for dust or fogging in the
LCD.
(2) SD card for recording checking.
(3) Mode: AUTO
(4) Check that the camera beeps.
(5) <DISP/BACK>
(6) Check that the live image and text is
displayed.
(7) Check that the live image is
displayed.
(8) Monitor a very bright subject and
check that the live image does not
dim or darken.
(1) Check that there is no abnormal
noise.
(2) Check that there is no edge blurring
Check that the screen display
accurately tracks zooming.
(3) Check that the zoom moves
smoothly.
(1) Check for problems on the LCD
monitor.
Check that the camera recovers
from synchronicity disruption.
(Note) Do not apply shocks directly
to the lens or card cover.
(2) Press the 4-way button (left) and
check that the Macro icon (tulip)
appears on the LCD monitor.
(4) The indicator lamp lights green ->
Intermittently lights orange or green
(recording) -> Turns off.
Measuring
equipment and jigs
CR0130900U9
ZPU0512-100
ZJ00525-100

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents