Siemens SCALANCE M-800 Series Getting Started page 59

Simatic net industrial remote communication
Hide thumbs Also See for SCALANCE M-800 Series:
Table of Contents

Advertisement

Requirement
● An NTP server can be reached in the local network.
● The IP address of the NTP server is known.
For this example, a local time server with the IP address 192.168.100.87 is used.
Procedure
1. Click on "System" > "System Time" in the navigation area and on the "NTP Client" tab in
the content area.
2. In "Time Zone", enter the local time difference to world time (UTC). For Central European
Summer time (CEST) +02:00.
3. In "NTP Server IP Address", enter the IP address 192.168.100.87. It is not possible to
enter the NTP address as a host name.
4. If necessary, change the port in "NTP Server Port". As default, 123 is set.
5. In "Poll Interval (s)", enter the interval for synchronization. As default, 64 is set.
6. Select NTP Client".
7. Click "Set Values".
SCALANCE M-800 Getting Started
Getting Started, 06/2015, C79000-G8976-C337-04
Connecting SCALANCE M-800 to WAN
1.3 Connecting M826 with SHDSL
59