VPN tunnel between SCALANCE M-800 and S612
3.4 Firewall with a VPN connection
Result
If "Auto Firewall Rule" is enabled, the following firewall rules are active.
Action
Allow
Allow
Allow
Allow
With these firewall rules, data traffic between internal network 1 and internal network 2 is
possible without any restrictions.
HTTP-based access to the remote VPN partner is not allowed. The appropriate firewall rule
is created in the section "Creating firewall rules manually (Page 139)".
138
From / to
Permitted proto-
cols
VPN tunnel /
TCP / UDP /
internal network
ICMP
1
VPN tunnel /
TCP / UDP /
internal network
ICMP
2
internal network
TCP / UDP /
2 / VPN tunnel
ICMP
internal network
TCP / UDP /
1 / VPN tunnel
ICMP
For
Source IP ad-
dresses
all ports or all ICMP
192.168.100.0/
packet types
24
all ports or all ICMP
192.168.11.0/2
packet types
4
all ports or all ICMP
192.168.11.0/2
packet types
4
all ports or all ICMP
192.168.100.0/
packet types
24
SCALANCE M-800 Getting Started
Getting Started, 06/2015, C79000-G8976-C337-04
Dest. IP
addresses
192.168.11.0
/24
192.168.100.
0/24
192.168.100.
0/24
192.168.11.0
/24