Siemens 1FT6 13 Instructions Manual page 14

Three-phase servomotors
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 9
Cooling
(EN 60034-6)
A-grade measuring-surface sound-pressure level
(EN 60034-9) for speed range up to 3,000 rpm; Tolerance +3 dB (A)
Self and water cooling
Forced ventilation
Thermal motor protection
(EN 60034-11)
Shaft end
(DIN 748-3; IEC 60072-1)
True running, coaxiality, axial run-out deviation Tolerance N
(DIN 42955; IEC 60072-1)
Vibration severity
(EN 60034-14)
Bearing
Service life of bearing
Winding insulation
(EN 60034-1)
Ambient temperatures
if water-cooled
Installation altitude
(EN 60034-1)
Magnetic material
Electrical Connection
Power
Encoder signal:
Encoder system
Additional technical parameters, dimensional sheets according to project planning guide
6SN1197-0AA20.
Options/expansions
Degree of protection
(EN 60034-5)
Fitted/mounted
14
ENGLISH
Self-cooling
Forced ventilation
Water-cooling
approx. 70 dB(A)
approx. 74 dB(A)
KTY84 temperature sensor in the
stator winding
cylindrical; without keyway
and without key
grade N
Rolling contact bearing with permanent
grease lubrication (lifetime lubrication)
Fixed bearing on the drive end
20000 h (recommended value)
Insulating material class F
-15 °C to +40 °C (5 °F to 104 °F)
+5 °C to +40 °C (41 °F to 104 °F)
≤ 1000 m [3280 ft.] above mean sea level
otherwise the rated data are reduced
2000 m [6562ft] conversion factor 0,94
2500 m [8202ft] conversion factor 0,9
Rare-earth material
Terminal box
Connector
Connector
fitted encoder
- speed recording
- recording the rotor position
- indirect positional recording
IP 65, IP67, IP68
(forced ventilation module IP54)
- closed current holding brake;
supply voltage 24 V DC ±10% /
230 V AC ±10%
- Planetary gearing
610.43 600.21
Siemens AG

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1ft6 16

Table of Contents