High temperature and high humidity.
Corrective Action
If the defect is worse than the defect sample, replace the Developer Unit (PL 5.2).
Reversion 4.0
WorkCentre 7132
59mm Pitch Density Non-Uniformity Defect
Figure 1 59mm Pitch Density Non-Uniformity Defect Sample (VA-004)
Cause
The 59mm Pitch Density Non-Uniformity is on printed sheets printed in the Half-Tone image of
the secondary color. The defect is more visible on the first print job when the machine is left in
a high temperature and high humidity environment overnight or longer.
Corrective Action
If the defect is worse than the defect sample, replace the Developer Unit (PL 5.2).
January 2007
Auger Marks Defect (Magenta), 59mm Pitch Density
3-31
Image Quality