2
1
Fig. 1
4. Plug the power cord into an AC power source (100-240V). Charging will begin. Refer to Table 1 in the Specifications
section for a list of charger LED displays and meanings.
5. Battery pack removal (Fig. 2):
° Release battery pack from cradle – press blue release tab on battery pack and lift out.
The TR-340 can remain attached to the TR-944N if desired. To release the cradle from the base – press down on
the oval release tab on the base, slide cradle forward and lift out. Be careful not to pinch fingers as the cradle slides
forward.
Battery pack charge status is indicated by pressing the indicator button on the top of the battery pack (Fig. 3). Number
of bars illuminated indicates approximate battery pack charge capacity (less than 20% to 100%). Refer to the battery
pack and charger User Instructions for further information on charging, charge status and service life of the battery
packs.
Fig. 2

Install and remove the Battery Pack into the TR-300

To install a charged battery pack, hold the unit so the filter cover faces you (Fig. 4):
° Inspect the hinge and latch on the battery pack and ensure it is clean and undamaged.
° Hook the left edge of the battery pack into its holder on the bottom of the unit (1).
° Push the right side of the battery pack into the motor/blower until the latch fully engages with an audible
click (2).
° Grasp the battery pack and gently pull to confirm pack is locked into place.
To remove the battery pack, hold the unit so the filter cover faces you. Press the battery pack latch and pull the battery
pack down and out.