TK-5400
Item
Condition
13. APCO high 1) Set panel tuning mode.
deviation
CH : 4 (Center)
adjustment
LCD display : HDVA t LO
(TA)
Deviation meter filter setting
LPF : 3kHz
HPF : OFF
De-emphasis : OFF
DET : Peak (+/–)
PTT : ON
Press [Side 2] to store the
digit number after adjustment.
14. APCO high 1) Set panel tuning mode,
deviation
then press [Orange] key to
adjustment
enter the 3 point adjustment
at low
mode.
frequency
LCD display : HDVA tL LO
(TA)
PTT : ON
Press [Side 2] to store the
digit number after adjustment.
15. APCO high 1) Set panel tuning mode,
deviation
and press [Side 2] key to set
adjustment
high frequency.
at high
LCD display : HDVA tH LO
frequency
PTT : ON
(TA)
Press [Side 2] to store the
digit number after adjustment.
16. FM wide
1) Set panel tuning mode.
deviation
CH : 4 (Center)
adjustment
LCD display : FMWD LO
Deviation meter filter seting
LPF : 15kHz
HPF : OFF
De-emphasis : OFF
DET : Peak (+/–)
MIC input : 150mV/1kHz
PTT : ON
Press [Side 2] to store the
digit number after adjustment.
17. FM wide
1) Set panel tuning mode.
deviation
CH : 4 (Center)
adjustment
LCD display : FMWD t LO
(TA)
PTT : ON
Press [Side 2] to store the
digit number after adjustment.
18. FM narrow 1) Set panel tuning mode
deviation
CH : 4 (Center)
adjustment
LCD display : FMND LO
Deviation meter filter setting
HPF : 15kHz
LPF : OFF
De-emphasis : OFF
DET : Peak (+/–)
MIC input : 150mV/1kHz
PTT : ON
Press [Side 2] to store the
digit number after adjustment.
34
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Deviation
Panel
ANT
Panel
Deviation
Panel
ANT
meter
Oscilloscope
AG
Side
Universal
Adjustment
Parts
Method
Top 1/ 2827Hz
2771~2883Hz
Top 2
± 50Hz
4.0kHz
± 50Hz
2.0kHz
Specifications/Remarks