FMWD
FM WIDE Max Deviation
LO
[Side 2]
FMWD
FM WIDE Max Deviation TA
t LO
[Side 2]
FMND
FM NARROW Max Deviation
LO
[Side 2]
FMND
FM NARROW Max Deviation TA
t LO
[Side 2]
QTDV
QT Deviation
LO
[Side 2]
QTDV
QT Deviation TA
t LO
[Side 2]
DQDV
DQT Deviation
LO
[Side 2]
DQDV
DQT Deviation TA
t LO
[Side 2]
DTDV
DTMF Deviation
LO
[Side 2]
DTDV
DTMF Deviation TA
t LO
[Side 2]
SQ O
FM WIDE Squelch Threshold
[Orange] : Write data
[Side 2]
RSSI Threshold
RRSI
[Orange] : Write data
[Side 2]
RSSI Low Level
LRSI
[Orange] : Write data
[Side 2]
SQ T
FM WIDE Squelch Tight
[Orange] : Write data
[Side 2]
RSSI High Level
HRSI
[Orange] : Write data
[Side 2]
FM NARROW Squelch Threshold
NSQO
[Orange] : Write data
[Side 2]
NSQT
FM NARROW Squelch Tight
[Orange] : Write data
[Side 2]
Battery Level
BATT
[Orange] : Write data
[Side 2]
END
ADJUSTMENT
Deviation adj. (Center)
Deviation TA adj. (Center)
Deviation adj. (Center)
Deviation TA adj. (Center)
Deviation adj. (Center)
Deviation TA adj. (Center)
Deviation adj. (Center)
Deviation TA adj. (Center)
Deviation adj. (Center)
Deviation TA adj. (Center)
Threshold Level writing. (Center)
RSSI REF Level writing. (Center)
RSSI Low Level writing. (Center)
Tight Level writing. (Center)
RSSI High Level writing. (Center)
Threshold Level writing. (Center)
Tight Level writing. (Center)
Battery Warning Level writing
BER (Bit Error Rate) Measurement
1. The Panel Test Mode is used to measure the BER with
the TK-5400 (see 1. Panel Test.).
2. Select a filter to be measured (see Filter Mode.).
3. Select a frequency to be measured (see Test Fre-
quency.).
4. Select "15" for test signaling (see Test Signaling.).
(If there is no RF input signal, the display shows
".999999".)
5. Enter a standard input signal into the receiver as a stan-
dard tone test pattern.
6. Adjust the input signal level to achieve the standard bit
error rate (BER).
(For example, if the BER is 5%, the display shows
".050000".)
C4FM (APCO) Deviation Adjustment
1. The TK-5400 adjusts the deviation between High Devia-
tion ± 1800Hz and Low Deviation ± 600Hz for the C4FM
(APCO).
2. The Symbol Rate Pattern is used when adjusting the
High Deviation for the C4FM (APCO) (see Test Signal-
ing.). This test signal has a peak deviation equal to 2/π
1800Hz = 2827Hz.
3. The Low Deviation Pattern is used when checking the
Low Deviation for the C4FM (APCO) (see Test Signal-
ing.). This test signal has a peak deviation equal to 2/π
600Hz = 942Hz.