Viessmann VITOCROSSAL 200 CM2 Service Instructions For Contractors page 71

400 to 620 kw gas condensing boiler with matrix cylinder burner, for open flue and room sealed operation, permissible operating pressure 6 bar
Hide thumbs Also See for VITOCROSSAL 200 CM2:
Table of Contents

Advertisement

Keyword index
A
Air pressure switch
– Combustion chamber pressure monitoring (LDW2)58
– Fan pressure monitoring (LDW1)............................58
B
Boiler, opening........................................................... 10
Boiler door
– Gaskets................................................................... 25
– Opening...................................................................24
Boiler water requirements.......................................... 64
Burner
– Cleaning.................................................................. 28
Burner control unit
– Display and programming unit................................ 34
– Flow diagram...........................................................38
Burner gauze assembly check................................... 26
C
CO2 content, checking...............................................21
CO2 test
– At the lower heating output..................................... 22
– At upper heating output...........................................22
– Preparation..............................................................21
Codes at the control unit, adjusting............................33
Combustion chamber, cleaning..................................24
Component overview................................................. 57
Condensate drain.......................................................26
Condensate drain system.......................................... 25
Connection diagram
– Burner control unit...................................................59
– Mains filter unit........................................................ 61
Conversion
– LPG P......................................................................14
– Natural gas LL.........................................................13
D
Diagnosis table...........................................................40
Display and programming unit
– Configuration display...............................................35
– Information display.................................................. 35
– Operating display.............................................. 34, 40
– Service indicator......................................................37
E
Expansion vessel....................................................... 32
F
Fan
– Fitting...................................................................... 28
Fault code.................................................................. 40
Fault memory............................................................. 40
Faults without fault display......................................... 45
Final checks, performing............................................ 31
Flow pressure check.................................................. 17
G
Gaskets and thermal insulation sections, checking... 25
Gas restrictor..............................................................68
Gas side connections, checking.................................31
Gas train valves, checking......................................... 30
Gas type check.......................................................... 12
H
Heating surfaces, cleaning.........................................24
Heating water side connections, checking................. 25
I
Ignition electrodes, checking......................................28
Internal system faults................................................. 43
Ionisation current display........................................... 23
Ionisation electrode, checking....................................28
L
LPG settings on burner control unit............................14
M
Manufacturer's certificate........................................... 70
Mixer, checking.......................................................... 32
N
Neutralising system....................................................26
O
Operating parameters, changing................................36
– Maximum operational output...................................36
Operating parameters, resetting................................ 37
Operational output reduction................................16, 36
Overview of steps.........................................................8
P
Packaging disposal...................................................... 5
R
Report
– Settings and test values.......................................... 62
– Water quality........................................................... 62
Reports.......................................................................62
Restrictor installation (for LPG P)...............................14
Rotary damper........................................................... 60
S
Servomotor.................................................................60
Setting check
– High limit safety cut-out...........................................10
– Rotary damper........................................................ 18
Settings and test values............................................. 62
Specification...............................................................66
Static pressure check.................................................17
Supply pressure check...............................................17
System
– Commissioning........................................................15
– Filling with water and venting.................................. 10
System pressure, checking........................................ 32
T
Trap, filling..................................................................10
Keyword index
71