Wiring; Dismantle The Bed - Invacare Etude Plus HC User Manual

Bed
Hide thumbs Also See for Etude Plus HC:
Table of Contents

Advertisement

Bed end motor, head end F
Hand control G

3.4 Wiring

IMPORTANT!
– The cables must be mounted in such a way
that they are kept clear off the floor and do
not block the castors. Mount the mains cable
on the hook for this purpose, see image.
In order to prevent the cables from being damaged when
activating the motors, follow the instructions below.
1. Connect the cables of the bed end motors (head and
foot end) directly to the control box.
2. The plug of the thigh motor must be directed through
the opening of the supporter for the backrest motor and
then connected to the control box.
3. Connect the main cable plug to the power socket.
1579562-B
4. Run the motors of the bed ends to their top position.
5. Place the motor cable of the foot end on the hook at
the foot end.
6. Run the backrest to its top position.
7. Place the head end motor cables on the four hooks at
the head end.
8. Attach the locking cam over the plugs in the control box.

3.5 Dismantle the bed

1. Dismantle side rails or wooden side panel and lifting
pole.
2. Bring the bed to its lowest position and adjust all
mattress support sections to horizontal position.
3. Disconnect main power supply. Roll the cable onto the
hook of the head end of the bed.
4. Dismantle the locking cam from the control box with a
tool, e.g. a flat headed screwdriver.
5. Disconnect all cables from the control box.
6. Separate the mattress support from the bed ends.
7. Divide the upper and lower halves of the mattress
support.