Zenith HydroTap G4
®
Installation and Operating Instructions
BC Residential
Affix Model Number Label
Here
802253NZ
802253NZ - HT BC Residential Instructions 10.18 v3.00
Page 1 of 28

Advertisement

Table of Contents
loading

Summary of Contents for Zenith HydroTap G4

  • Page 1: Step

    Zenith HydroTap G4 ® Installation and Operating Instructions BC Residential Affix Model Number Label Here 802253NZ 802253NZ - HT BC Residential Instructions 10.18 v3.00 Page 1 of 28...
  • Page 2: Step

    Tap Options The Zenith HydroTap G4 appliance series offers a range of interchangeable taps to suit the customer’s needs Classic Tap These taps are directly compatible with the HydroTap G4 Command Centre. Arc / Cube Tap Elite Tap The Mixer tap range is an additional series of taps that...
  • Page 3: Table Of Contents

    Index HydroTap Specifications Installation Checklist ........................4 General Product Features ......................5 Important Safety Instructions ....................... 6 Warnings and Regulatory Information ..................7 Major Components and Accessories ................... 8 Technical Specification ........................ 9 Before Installation and Site Requirements ................... 10 Installation Instructions STEP 1 - Fit the tap to the benchtop or sink before installing the undersink unit.
  • Page 4: Installation Checklist

    Installation Checklist Before Installation: Read the instructions and check if there is adequate space to mount all of the components. Note: Not all fittings are supplied with the appliance kit. Isolation valves are not supplied. Check the mains water pressure is between 150 - 700kPa and 200 - 700kPa when a booster and /or filter softener is fitted Check the water quality to determine if extra filtration will be required.
  • Page 5: General Product Features

    Disabled use. The disabled levers are supplied with Braille caps for the visually impaired. Usage: The Zenith HydroTap is intended for use in residential household and similar applications such as, rural and urban residential Kitchens, Hotels, Motels, Bed and Breakfast and other residential type environments.
  • Page 6: Important Safety Instructions

    Lifting Take care when lifting the Zenith HydroTap unit. Some units may exceed safe lifting limits. If you feel this is beyond your personal capabilities, please seek assistance with the lift. The weights of the units are marked on the packaging.
  • Page 7: Warnings And Regulatory Information

    WARNINGS 1. The Zenith HydroTap unit must be earthed. The resistance of the earth connection from each exposed metal part must be less than 1 ohm. 2. All Installation and service work must be completed by trained and suitably qualified Tradespeople.
  • Page 8: Major Components And Accessories

    Major Components and Accessories Parts supplied Description Accessories Description 1 x Tap option with hoses HydroTap Booster Water System with (Classic Tap shown) connection hoses 1 x HydroTap Undersink Unit with Font Kit for air and water filters Arc & Cube Models 1 x Mains water connection hose Font Kit for Classic &...
  • Page 9: Technical Specification

    Technical Specifications Models Boiling and Chilled BCHA 4 in 1 All in One - Mains All in One - Vented Disabled lever controls (optional accessory) Power Power Boost Unit Dimensions **Dry outlets Rating Rating W x D x H (mm) Weight required (kW)
  • Page 10: Before Installation And Site Requirements

    Before Installation Note: Check all cable and hose lengths against inlet /outlet positions before proceeding (See section 4 for general layout). • A potable water supply connection with isolating valve inside the cupboard within reach of the braided hoses and positioned so that the connection point and the stop cock will not be obstructed when the undersink units are installed.
  • Page 11: Section 2 - Ventilation

    Section 2 Ventilation Ventilation for All Models Proper air circulation must be provided for the system to operate correctly. Both the top and the front of the undersink unit must remain accessible for servicing. IMPORTANT: Allow a clearance envelope of 50mm either side, and 300mm above the undersink unit. Ventilation options will be dependent on usage.
  • Page 12: Cupboard Air Ciculation

    Ventilation When installing air flow ducts, the following tools will be required: • Jigsaw and 12mm Drill • Keyhole or Wall Board saw. The following instructions are critical if there is insufficient cupboard air circulation If the air flow using the silicon door buffers is insufficient, it will be necessary to fit a standard HydroTap vent kit, which ensures heat dissipation through natural convection via installed vents.
  • Page 13 Ventilation Typical Cut out procedure for 1. Mark out and cut the air inlet and door outlet holes as shown 2. Ensure the air inlet vent and air outlet vent are positioned at opposite ends of the same cupboard space. 3.
  • Page 14: Product Description

    It is intended to provide pre heating of water before it enters the Zenith HydroTap G4 boiling tank. The Booster is supplied as standard equipment with all 4-In-1 & BCHA-AV models. However, it may be later installed as an accessory to increase boiling water delivery.
  • Page 15: Installation Procedure

    Booster Installation Installation Procedure Site requirements • The appliance must only be installed in a frost-free area. Never expose the appliance to frost. • The appliance is designed for wall mounted Installation and must to be installed with water connectors facing upwards.
  • Page 16: Braided Hose Connections

    ‘Bypass Out’ fitting to the water inlet of the booster unit (marked blue), and from the outlet of the booster unit (marked red) to the ‘Bypass IN’ fitting on the Zenith HydroTap unit. Avoid exerting any mechanical pressure on the appliance. This can be achieved by applying a spanner on the flats of the inlet and outlet connections when tightening the braided hose connectors.
  • Page 17: Step

    The diverter bypass valve allows the user to choose to have the boiling feed water bypass the internal filter and only be filtered by external filtration. The diverter valve is located at the rear panel of the Zenith HydroTap undersink unit. Refer to the image below to determine the correct valve position.
  • Page 18: Model Bc 160/125 And Bc 160/175

    Installation Instructions Model: Boiling Chilled Note: the hoses need to have a constant downward gradient to the Hydrotap to allow all water to drain back into the tanks. BOILING BYPASS VENT BYPASS MAINS MIXER MIXER CHILLED Note: - Mains hose length is 750mm - Plug and Cord length is 1800mm...
  • Page 19: Model Aio Mains

    Installation Instructions Model: All-In-One Mains Pressure Note: the hoses need to have a constant downward gradient to the Hydrotap to allow all water to drain back into the tanks. BOILING BYPASS VENT BYPASS MAINS MIXER MIXER CHILLED Note: - Mains hose length is 750mm - Plug and Cord length is 1800mm...
  • Page 20: Model Aio Vented

    Installation Instructions Model: BCHA-A All-In-One Vented Booster HT Mixer Note: the hoses connections need to have a constant downward gradient to the Hydrotap to allow all water to drain back into the tanks. MAINS MIXER MIXER BOILING BYPASS VENT BYPASS CHILLED Note: - Mains hose length...
  • Page 21: Model 4-In-1 Vented

    Installation Instructions Model: BCHA-AV 4-In-One Vented HT Mixer Booster connections Note: the hoses need to have a constant downward gradient to the Hydrotap to allow all water to drain back into the tanks. BOILING MIXER BYPASS VENT BYPASS MAINS MIXER CHILLED Note: - Mains hose length...
  • Page 22: Section 5 - Commissioning

    Section 5 Commissioning • Turn ON the water and check for any leaks. • Turn the power ON at the power outlet and at the side of the undersink unit • If fitted, ensure the Booster is turned OFF (Booster is commissioned, later, at section 5.4) •...
  • Page 23: Boiling Calibration

    Commissioning Boiling Calibration • Press the calibration button and the system will commence the Boiling calibration procedure. This will take approx 5-6 minutes. Booster • Upon completion, a Booster reminder screen will appear and allow you to return home by pressing the [Home] button.
  • Page 24: Sensor

    Safety Sensor Calibration (Lever taps) Sensor Light intensity varies from site to site, therefore it is recommended that a re-calibration be performed at the time of the installation. All direct natural sun light must be shaded from the HydroTap, during the calibration. This can be achieved by closing any nearby curtains, blinds, or by shielding the HydroTap with a dark cloth.
  • Page 25: Troubleshooting

    Flow Sensor Fault Internal fault Call Zenith Service Call an electrician, a plumber, or Zenith free call in NZ on 0800 558 055 for assistance, service, spare parts or enquiries. 802253NZ - HT BC Residential Instructions 10.18 v3.00 Page 25 of 28...
  • Page 26: End Of Life Disposal

    End of Life Disposal In order to help preserve our environment we ask that you dispose of this product correctly. Please contact your local city council for collection centre details. Page 26 of 28 802253NZ - HT BC Residential Instructions 10.18 v3.00...
  • Page 27 Notes 802253NZ - HT BC Residential Instructions 10.18 v3.00 Page 27 of 28...
  • Page 28: Contact Details

    Images in this booklet have been modified and may not be true representations of the finished goods. The terms “Zenith” and “HydroTap” are registered trade marks of Zenith Heaters Ltd. Products described in this publication are manufactured under one or more patents and further patent applications are pending.