description
Tubing OD, mm (in)
Tubing ID, mm (in)
Prepare Tubing
1. Cut the tube squarely and remove any burrs.
2. Mark from end of tube the length of insertion. The insertion lenght of Midas-Mfrom the end
of tube is 15.5 mm.
NOTE
When inserting the tube into the inlet/outlet port of the Midas-M, make sure that it is
inserted up to the marked position.

In-Line Filters

External filters must be used to protect the tubing from contamination. Use particulate filter part
number 780248 for normal gases and 1830-0055 or 1991-0147 for corrosive gases. Replace
the filter every 3 months. Refer to the Gases Table for specific gases.

Local Detector Option

The Midas-M gas detector can also be used to monitor for gas at the location of the detector. To
do this, an inline filter is simply connected to the sensor cartridge gas inlet port. The external
dust filter part number is 780248 for normal gases and 1830-0055 or 1991-0147 for corrosive
gases. The area around the detector is then being monitored as opposed to a sample being
drawn from a remote location.
Midas-M
maximum
6.35 (0.25)
4.76 (0.188)
18