FS20X Fire and Flame Detectors
Features and Benefits
● Selectable sensitivity (four settings)
User can set the detector to any of four detection distances (see
the Detector" on page
● Selectable relay options
User-configurable for a variety of dry contact relay interface options (see
"Configuring the Detector" on page
● Selectable 4 – 20 mA output
Source or sink output options (see
● Selectable communications
Configurable for analog or digital communication outputs such as ModBus (see
"Configuring the Detector" on page
● Selectable digital communication address
The user can select a unique 7-bit code (128 addresses, see
Detector" on page
● Lower power consumption
Requires smaller external power supplies and fewer system backup batteries.
● Multiple microprocessors
Reduces the number of discrete detector components, provides larger
programming and memory capacity, and provides redundant self-checking.
● Wider range of applications
Primary applications include long range, fast response to fires such as
acetylene, silane, hydrogen, etc.
● Wider operating temperatures
-40°F to +185°F (-40°C to +85°C) standard
● Built-in automatic "through-the-window" self-test
Monitors window obscuration and checks the operation of the detector's sensor
array and electro-optical electronics module with built-in IR and UV self-tests.
● Anodized removable aluminum detector module
Rugged, superior protection against EMI/RFI and handling plus simple field
installation and replacement.
● Three bright LEDs (red, yellow, green)
Field status indicators with individual LEDs for alarm, fault, and normal
conditions. Provides superior detector status viewing in bright outdoor
environments (see
● Windows-based PC interface
User can perform remote FS20X Detector diagnostics, real-time status,
Real-Time Graphing (RTG™), SnapShot™ data recording, and downloading
FirePics™ with Honeywell Analytics' exclusive FSIM-2 USB Interface Unit and
easy-to-use Windows-based PC Software.
● Designed to detect both hydrocarbon and non-hydrocarbon fires with a single
FSX™ detector
All fire and flame threats are sensed, not just hydrocarbon fires as with other
triple IR flame detectors.
● FM 3260 approved
Third-party tested and certified for industrial and commercial applications.
● Designed, manufactured, and tested by Honeywell Analytics
Over thirty years of proven fire/flame detection product excellence worldwide.
10
31).
31).
"Configuring the Detector" on page
31).
31).
"Fault Conditions" on page
"Configuring
"Configuring the
36).
31).