Mira Bijou Installation & User Manual page 10

Thermostatic mixers
Table of Contents

Advertisement

11. Fit the compression nuts and olives onto the
pipework.
12. Align the mixer with the pipework and fit onto
the backplate.
Important! make sure that the hot and cold
inlets on the mixer correspond with the hot and
cold inlet supplies.
13. tighten the compression nuts onto the mixer
with a suitable spanner.
Caution! take care not to damage the chrome
surfaces.
14. tighten the grubscrew to secure the mixer to
the backplate.
15. Fit the spacer and shelf onto the mixer. Use
a spirit level to make sure that the shelf is
level and tighten the fixing bolt using a 4 mm
hexagonal key (supplied).
Caution! do not overtighten.
Fixing Bolt
compression nut
olive
shelf
spacer
10
16. Fit the shower fittings, refer to your shower
fittings installation and user guide for
instructions.
Note! For user comfort on high pressure
systems, a 12 litre/minute flow regulator
(supplied) can be fitted inside the outlet nipple.
Make sure that the flow regulator is fitted
correctly (refer to illustration).
Important! The fitting of this flow regulator
will invalidate any tmV2 compliance due to
the minimum flow rate requirements, do not
fit the flow regulator in these applications.
Flow regulator
17. turn on the hot and cold water supplies and
check for leaks.
18. Before using the shower, refer to section:
'Commissioning'.

Hide quick links: