10-7. How to Diagnose Trouble in Outdoor Unit

10-7-1. Summarized Inner Diagnosis of Inverter Assembly
Diagnosis/Process flowchart
Remove
connector of
compressor.
NG
Check 25A fuse
(Part No.F01).
OK
Replace fuse.
electrolytic
capacitor, diode
block (DB01),
Check
NG
15A fuse
(Part No.F03).
OK
Replace control
board assembly.
Check
NG
terminal voltage
of electrolytic
capacitor.
OK
electrolytic
capacitor, diode
NO
Does outdoor
fan rotate?
YES
Does LED on control
board flash or go on?
NO
Remove connector
CN300 of outdoor fan
NG
motor, and using a
tester, check resistance
value between every
phases at motor side.
OK
Replace
outdoor
fan motor.
A
B
Item
Preparation
Check
Check
Check
etc.
Check
(DB01),
etc.
Operation
Measurement
YES
Check
Stop
Check
Measurement
C
– 52 –
Contents
Turn "OFF" the power breaker,
and remove 3P connector
which connects inverter and
compressor.
• Check whether 25A fuse on
the control board assembly
is blown or not. (F01)
Check whether 15A fuse on
the control board assembly
is blown or not. (F03)
• 15A fuse (F03) on the
control board is provided for
power factor improvement
control circuit. The operation
continues even if fuse is
blown.
Turn on power breaker, and
operate the air conditioner in
COOL mode by short-circuit of
the timer.
Measure terminal voltage of
the electrolytic capacity.
500µF:400WV x 3
After operation, turn off the
power breaker after 2 minutes
20 seconds passed, and
discharge the electrolytic
capacity by soldering iron.
Check voltage between motor
phases.
Q
• Is not winding between
R
R
S
Q
S
,
-
, or
-
opened
or short-circuited?
• Is not frame grounded with
Q
R
S
,
, or
?
Summary
If fuse was blown, be sure to
check the electrolytic
capacitor and diode block.
(DB01)
• Connect discharge
resistance (approx.
100Ω40W) or soldering
iron (plug) between +, –
terminals of the electro-
lytic capacitor (500µF) of
C14 (with printed CAU-
TION HIGH VOLTAGE) on
P .C. board.
Plug of
Discharging position
soldering
(Discharging period
iron
10 seconds or more)
If 15A fuse is blown,
discharge both edges of
the electrolytic capacitor
with soldering iron.
OK if 500µF → → → → →
DC280 to 320V
Remove CN300 while
pushing the part indicated
by an arrow because CN01
is a connector with lock.
-
→ → → → → Resistance between
phases should be approx. 55
to 77Ω
→ → → → → Should be 10MΩ or more.