Wiring Connection - Toshiba RAS-10SA-E Service Manual

Split wall type
Hide thumbs Also See for RAS-10SA-E:
Table of Contents

Advertisement

8-4-3. Wiring Connection

WARNING
To plug the cable in the plug receptacle, take the
following precaution.
THIS APPLIANCE MUST BE EARTHED.
IMPORTANT
THE WIRES IN THIS MAINS LEAD ARE COLORED
IN ACCORDANCE WITH THE FOLLOWING CODE:
L
: Brown
N
: Blue
: Green and Yellow
As the colors of the flexible cord of this appliance may
not correspond with the colored markings, to identify
terminals in your plug, as follows:
Connect BROWN colored core to plug terminal marked
letter "L".
Connect BLUE colored core to plug terminal marked
letter "N".
Connect GREEN AND YELLOW colored core to plug
terminal marked Earth Symbol "
<How to remove the front cabinet>
4
2
1
Vertical air flow louver.
How to open the screw cap
• Place your finger on the lower part and push
up to open the screw cap.
(1) Open the screw caps and remove the two screws
securing the front cabinet.
(2) Close the screw caps as behind.
(3) Open the vertical airflow louver horizontally by
hand.
(4) Slightly open the lower part of the front cabinet
then pull the upper part of the front cabinet toward
you to remove it from the rear plate.
-LIVE
L
-NEUTRAL
N
-EARTH
Fig. 8-4-5
".
4
1
2
3
Fig. 8-4-6
Taking out the power cord
• Cut off the slitted portion in the side face of the
rear panel to take out the power cord. After
this, remove burrs, sharp edges, etc., to
smooth the cut face.
<How to connect the power cord>
For the air conditioner that has no power cord,
connect a power cord to it as mentioned below.
• After removing the front cabinet, remove the
terminal cover and the cord clamp.
• Connect and secure the power supply cord and
secure the cord clamp and the terminal cover.
• Cut the rear panel following the cutting mark and
put the power supply cord through the notch.
• Be sure to smooth out the notch with a file, etc.
Terminal block
<Stripping length of power cord>
L
N
10mm
NOTE :
• Use standard wire only.
• Wire type: More than H05-RN-F
– 24 –
Slitted portion
Cord clamp
Power supply
cord
Screw
L
N
Screw
Earth line
Fig. 8-4-7
30mm
10mm
Earth line
40mm
Fig. 8-4-8
Terminal cover
Screw

Hide quick links: