8-4. Indoor Unit

t Installation place
• A place which provides the spaces around the
indoor unit as shown in the diagram in section 8-2.
• A place where there is no obstacle near the air
inlet and outlet.
• A place which allows an easy installation of the
piping to the outdoor unit.
• A place which allows the front panel to be opened.
CAUTION
• Direct sunlight to the indoor unit wireless
receiver should be avoided.
• The microprocessor in the indoor unit should
not be too close to r-f noise sources. (For
details, see the owner's manual.)
<Remote control>
• A place where there are no obstacles such as a
curtain that may block the signal from the remote
control.
• Do not install the remote control in a place exposed
to direct sunlight or close to a heating source, such
as a stove.
• Keep the remote control at least 1 m apart from
the nearest TV set or stereo equipment. (This is
necessary to prevent image disturbances or noise
interference.)
• The location of the remote control should be
determined as shown below.
Remote
Reception
control
range
Fig. 8-4-1
(Top view)
Indoor unit
Reception
range
*:Axial distance
8-4-1. Cutting a Hole and Mounting
Installation Plate
<Cutting a hole>
When installing the refrigerant pipes from the rear
The center of the pipe
hole is the above arrow.
(1) After determining the pipe hole position with the
mounting plate (80 mm
mm) at a slight downward slant to the outdoor side.
NOTE :
• When drilling the wall that contains a metal lath,
wire lath or metal plate, be sure to use a pipe hole
brim ring sold separately.
<Mounting the installation plate>
For installation of the indoor unit, use the paper pattern
on the back.
65.5mm
Pipe
hole
Remote
control
Indoor unit
– 22 –
The center of the piping slot
is the above arrow.
Pipe hole
80mm
Fig. 8-4-2
), drill the pipe hole (ø65
Anchor bolt hole
Pipe hole
Thread
8 Mounting
screw
Weight
Fig. 8-4-3
65.5mm
1
Installation
plate